Weigh Count Systems - click here
DC150


 

Laser & CCD Scanners - click here


 

FX1 Parallel Beam Systems - click here


 

Bandolier / Surface Mount Count Systems - click here

SMD2000


 

Taping & Reeling Systems - click here

SMHT1100



Weigh Count Systems - click here


GSC9700



Bandolier / Surface Mount Count Systems - click here

SMD1316


KFC Company
PO Box 55
Cinderford
Gloucestershire
GL14 3YB



Office: (01594) 822025


Mobile: 07714 210345


Fax: (01594) 822195


Email us:
info@kfcco.com
 
 
 
 
 
 
 
 
 
 

Welcome Sales Section Hire Section

 

Back SMD2000 Spec SMD1316 Spec B530 Spec

SMD1316
Specification - Model 1316 – Surface mount Count System
The unit will normally be supplied as a retrofit assembly to our standard B530 Counter. It is not normally suitable for use with our B520 or B630 series counters. The unit may be simply and quickly attached to the standard B530 and does not preclude further use for the counting of standard axially and radial bandoliered components.

 

Loading the Tape:

The full reel should be mounted on the Left hand spool holder. Take the film leader and pass it along the slot round the toothed wheel, ensuring that it engages with the sprocket wheel teeth, and out through the slot on the far side. Feed the leader onto the empty spool fitted on the right hand spool holder, ensuring that the sprocket holes on the bottom of the tape engage with the teeth on the sprocket wheel. Fit the handle supplied such that the drive pins engage in the slots at the centre of the empty spool. As spool thickness' are not always consistent, try to ensure that the film carrier is as near horizontal as possible when passing through the guide path. This may be achieved by using suitable packing spacers under the reels. Set the film retaining guides such that they just ride lightly on top of the tape

Care should be taken when counting components carried in paper tape to avoid drawing the tape too quickly through the guidance system. Some paper tapes are quite stiff and will tend to snag in this situation, a steady pull is all that is needed to ensure trouble free operation. Do not on any account force the tape past the sprocket wheel, as damage will result. It is also beneficial to clamp or screw the base unit to a bench

Counting:

To maintain count veracity note should be taken on the number of components passing through the sprocket counting wheel on to the take-up spool, ignoring any length of empty leader. Components should normally be loaded such that the blister faces inward towards the counter body.

Start Point:

A small red arrow is fitted to the centre of the adaptor body, this indicates the start point of any count. The start point of the first pocket containing components should be aligned to this mark. The counter should then be reset to ZERO at this point (i.e. Depress the orange Button)

Counting small quantities:

The simplest way of counting small quantities i.e. less than full reel, is to pull the empty leader through to the RIGHT EDGE OF THE SMD ADAPTOR and then ZERO the count. Now observing the LCD Display, run up to the desired number of components and then CUT THE TAPE AT THE RIGHT HAND EDGE OF THE ADAPTOR. You will then have the correct number of components on your tape. This is simpler than marking the tape and counting off from that point. The method outlined can be compared to compensating for the weight of the pan when using comparative Weigh Scales

Specifications subject to change without notice. The unit will normally be supplied as a retrofit assembly to our standard B530 Counter. It is not normally suitable for use with our B520 or B630 series counters. The unit may be simply and quickly attached to the standard B530 and does not preclude further use for the counting of standard axially and radial bandoliered components.


Email now for further information on these products:
sales@kfcco.com

 

 

 